FreeBSD检查RAID阵列的状态
时间:2019-11-20 08:53:58 来源:igfitidea点击:
如何在Linux下检查Adaptec RAID阵列的运行状况。
如何查看阵列卡的状态?
在FreeBSD中, aac是Adaptec AdvancedRAID Controller驱动程序。
查看有关RAID设备的信息
执行以下命令:
# dmesg | grep -i RAID
输出示例:
aac0: mem 0xe8000000-0xe81fffff irq 16 at device 0.0 on pci6 aacd0: on aac0
# pciconf -l | grep -i aac
输出:
aac0@pci0:6:0:0: class=0x010400 card=0x02d19005 chip=0x02859005 rev=0x09 hdr=0x00
FreeBSD arcconf
arcconf是Adaptec SCSI RAID系列RAID控制器的命令行界面,用于配置和管理连接的存储设备。
它可用于获取有关RAID配置的详细信息,包括RAID的运行状况。
在FreeBSD中安装arcconf
执行以下命令:
# portsnap fetch update # cd /usr/ports/sysutils/arcconf # make install clean && rehash
如何使用arcconf来查看Adaptec RAID阵列的状态?
获取控制器1的信息:
# /usr/local/sbin/arcconf getconfig 1
输出示例:
Controllers found: 1 ---------------------------------------------------------------------- Controller information ---------------------------------------------------------------------- Controller Status : Optimal Channel description : SAS/SATA Controller Model : Adaptec 5405 Controller Serial Number : 8C4310BD20D Physical Slot : 2 Temperature : 58 C/ 136 F (Normal) Installed memory : 256 MB Copyback : Disabled Background consistency check : Disabled Automatic Failover : Enabled Global task priority : High Performance Mode : Default/Dynamic Stayawake period : Disabled Spinup limit internal drives : 0 Spinup limit external drives : 0 Defunct disk drive count : 0 Logical devices/Failed/Degraded : 1/0/0 -------------------------------------------------------- Controller Version Information -------------------------------------------------------- BIOS : 5.2-0 (16501) Firmware : 5.2-0 (16501) Driver : 5.2-0 (16501) Boot Flash : 5.2-0 (16501) -------------------------------------------------------- Controller Battery Information -------------------------------------------------------- Status : Optimal Over temperature : No Capacity remaining : 99 percent Time remaining (at current draw) : 3 days, 0 hours, 52 minutes ---------------------------------------------------------------------- Logical device information ---------------------------------------------------------------------- Logical device number 0 Logical device name : RAID1-A RAID level : 1 Status of logical device : Optimal Size : 285686 MB Read-cache mode : Enabled Write-cache mode : Enabled (write-back) Write-cache setting : Enabled (write-back) when protected by battery Partitioned : Yes Protected by Hot-Spare : No Bootable : Yes Failed stripes : No Power settings : Disabled -------------------------------------------------------- Logical device segment information -------------------------------------------------------- Segment 0 : Present (0,0) 3LM44BDA00009839M228 Segment 1 : Present (0,1) 3LM4C6B000009841PEW9 ---------------------------------------------------------------------- Physical Device information ---------------------------------------------------------------------- Device #0 Device is a Hard drive State : Online Supported : Yes Transfer Speed : SAS 3.0 Gb/s Reported Channel,Device(T:L) : 0,0(0:0) Reported Location : Connector 0, Device 0 Vendor : SEAGATE Model : ST3300655SS Firmware : 0004 Serial number : 3LM44BDA00009839M228 World-wide name : 5000C50006EDAD74 Size : 286102 MB Write Cache : Enabled (write-back) FRU : None S.M.A.R.T. : No Device #1 Device is a Hard drive State : Online Supported : Yes Transfer Speed : SAS 3.0 Gb/s Reported Channel,Device(T:L) : 0,1(1:0) Reported Location : Connector 0, Device 1 Vendor : SEAGATE Model : ST3300655SS Firmware : 0004 Serial number : 3LM4C6B000009841PEW9 World-wide name : 5000C50006EF88D8 Size : 286102 MB Write Cache : Enabled (write-back) FRU : None S.M.A.R.T. : No Command completed successfully.